Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 27, 2022, 08:57 AM
  • 02 0027_02 0026_5272022_020244.mp4

Date
05/27/2022
W/O
0957066
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00234
PipeID
P03058
Time
1:57 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3108
Sewer Name
02 ARTESIA EXTENSION TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
39
Purpose
Capital Improvement Program Assesment
Project
20220527MDM_ARTESIA_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0026
Downstream MH
02 0027
Dir. of Survey
Upstream
Length Surveyed
329.7 ft.
Total Length
329.7 ft.
Structural Index
3
Structural Quick
443A
Structural Rating
76
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
76
Pipe schematic from manhole 02 0026 to 02 0027
MH: 02 0026MH: 02 0027upstream0 ft. AMH - Upstream Manhole, Survey Ends - 2:45AM0.6 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0.6 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL40.1 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL47 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"50.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped54.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT68.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open113.9 ft. FC - Fracture Circumferential, from 03 to 05 o'clock, within 8 inches of joint: YES - SKL129.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT144.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open146.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL148.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped169.7 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H199.8 ft. FC - Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES - SL217.8 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL235.3 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - H241.6 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL246 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open248 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped249.5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H252.7 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL261.6 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - SL267.2 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H270.5 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H273.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H282.4 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H288.7 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SL297 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL306.4 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H309.5 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL309.5 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL310.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 5" - Open312.6 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - H318.7 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SLIGHT318.7 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - SL321.5 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - H321.5 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - HAIRLINE329.7 ft. MWM - Water Mark, 20 %of cross sectional area329.7 ft. AMH - Upstream Manhole, Survey Begins - 2:00AM329.7 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

    183.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

Observations (42)

DistanceCodeObservation
11FCSLIGHT
23.3FLH
275.1FMSLIGHT
129.9FCSL
160FLH
200.4FMSLIGHT
261TFOpen
279.4TFCCapped
80.2FLH
181.6TFCCapped
20.2FCSL
88.1FCSL
0MWM
41FCSL
325.7FMSL
8.2FLH
17.1FLH
68.1FLSL
32.7FCSL
47.3FLH
184.9TFOpen
215.8FCSKL
19.5TFOpen
0AMH2:00AM
329.1MGOConn. @ Mh, 9 O' Clock. Active
20.2FCSL
83.7TFOpen
282.7TFC
111.9FCSL
94.4FLH
329.1MGOConn. @ Mh, 3 O' Clock. OPEN
59.2FLH
289.6FCSL
56.1FLH
77FCSL
62.5FLH
8.2FLHAIRLINE
183.1FMSL
329.7AMH2:45AM
81.7TFCCapped
0MWL
11FCSL

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2022-05-27T01:57:30-07:00
documentation
MARTIN,IGNACIO
is_lateral_inspection
false