Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2022, 10:12 AM
  • 18 0107_18 0106_04272022_043009.mp4

Date
04/27/2022
W/O
952101
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13927
Time
3:12 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10082
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_952101_TV18177_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0106
Downstream MH
18 0107
Dir. of Survey
Upstream
Length Surveyed
310.9 ft.
Total Length
310.9 ft.
Structural Index
3
Structural Quick
3S2K
Structural Rating
419
O&M Index
2
O&M Quick
2K00
O&M Rating
122
Overall Index
2
Overall Quick
Overall Rating
541
Pipe schematic from manhole 18 0106 to 18 0107
MH: 18 0106MH: 18 0107upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 01070 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE2.9 ft. MGO - General Observation - ROACHES @ MH2.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish8.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"11.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"57.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"60.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"108.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN112.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"160.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN164 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"190.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start209.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN212.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN258.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - 10% GREASE-LATERAL261.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"308.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start308.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start308.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start310.9 ft. MGO - General Observation - ROACHES @ MH310.9 ft. AMH - Downstream Manhole, Survey Begins - 18 0106310.9 ft. MWM - Water Mark, 15 %of cross sectional area310.9 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    120.1 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (27)

DistanceCodeObservation
52.7TF10% GREASE-LATERAL
0MGOROACHES @ MH
0AMH18 0106
0MWM
101.4TFOPEN
49.6TFC
308MGOROACHES @ MH
308DAGS
98.5TFOPEN
308SAV
302.4TFA
198.6TFC
2DAGS
202TFOPEN
299.6TFC
146.9TFC
150.5TFOPEN
310.9AMH18 0107
2SSS
308SSS
308FL
2.6SAV
250.7TFC
0MWL
310.9MGOCONN @ MH 9 O'CLOCK/ACTIVE
253.7TFC
120.1FL

Properties (7)

additional_info
630074042622202
custom_field_three
AGGREGATE VISIBLE/FRACTURE'S
custom_field_two
3
customer
1
datetime
2022-04-27T03:12:51-07:00
documentation
PROPIPE
is_lateral_inspection
false