- Date
- 04/27/2022
- W/O
- 952101
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00698
- PipeID
- P13925
- Time
- 2:50 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10082
- Sewer Name
- 18 SANTA FE STREET TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 22
- Purpose
- Routine Assessment
- Project
- RFIR_WO_952101_TV18177_MAY2022
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 18 0104
- Downstream MH
- 18 0105
- Dir. of Survey
- Upstream
- Length Surveyed
- 169.9 ft.
- Total Length
- 169.9 ft.
- Structural Index
- 3
- Structural Quick
- 3F2F
- Structural Rating
- 165
- O&M Index
- 2
- O&M Quick
- 2F00
- O&M Rating
- 66
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 231
Pipe schematic from manhole 18 0104 to 18 0105 Observation photos (2)

3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

131.9 ft. - Tap Saddle, at 09 o'clock, -, within 8 inches of joint: NO, 6"