Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 2, 2022, 09:31 AM
  • 18 0091_18 0090_05022022_034709.mp4

Date
05/02/2022
W/O
952101
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13910
Time
2:31 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10086
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_952101_TV18177_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0090
Downstream MH
18 0091
Dir. of Survey
Upstream
Length Surveyed
353.4 ft.
Total Length
353.4 ft.
Structural Index
3
Structural Quick
3M2M
Structural Rating
353
O&M Index
2
O&M Quick
2M00
O&M Rating
142
Overall Index
2
Overall Quick
Overall Rating
495
Pipe schematic from manhole 18 0090 to 18 0091
MH: 18 0090MH: 18 0091upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 00910.4 ft. MGO - General Observation - ROACHES @ MH2.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish34.5 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES51.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"57.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"84.8 ft. TSI - Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - OPEN254.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"351.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start351.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start351.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start353.4 ft. AMH - Downstream Manhole, Survey Begins - 18 0090353.4 ft. MWM - Water Mark, 30 %of cross sectional area353.4 ft. MWL - Water Level, 25 %of cross sectional area353.4 ft. MGO - General Observation - ROACHES @ MH

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - OPEN

    268.6 ft. - Tap Saddle Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - OPEN

  • Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    318.9 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
353MGOROACHES @ MH
296TFC
0AMH18 0090
0MWM
318.9FL
353.4AMH18 0091
302.2TFC
2.3SAV
98.8TFC
351SSS
2DAGS
0MWL
2SSS
351DAGS
350.9SAV
0MGOROACHES @ MH
268.6TSIOPEN

Properties (7)

additional_info
630074050222002
custom_field_three
AGGREGATE VISIBLE/FRACTURE
custom_field_two
3
customer
1
datetime
2022-05-02T02:31:37-07:00
documentation
PROPIPE
is_lateral_inspection
false