Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 5, 2022, 06:15 AM
  • 18 0084_18 0083_05052022_003225.mp4

Date
05/04/2022
W/O
952101
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00698
PipeID
P13903
Time
11:15 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10089
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_952101_TV18177_MAY2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0084
Downstream MH
18 0083
Dir. of Survey
Downstream
Length Surveyed
385 ft.
Total Length
385 ft.
Structural Index
3
Structural Quick
423O
Structural Rating
400
O&M Index
2
O&M Quick
2N12
O&M Rating
154
Overall Index
2
Overall Quick
Overall Rating
554
Pipe schematic from manhole 18 0084 to 18 0083
MH: 18 0084MH: 18 0083downstream0 ft. MGO - General Observation - ROACHES @ MH0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 00842 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start8.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6"86 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"87.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"88.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES144.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES157.3 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6"167.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES202.4 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES256.4 ft. RFJ - Roots Fine Joint, from 09 to 02 o'clock, within 8 inches of joint: YES276.6 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6"296.4 ft. RFJ - Roots Fine Joint, from 08 to 03 o'clock, within 8 inches of joint: YES343.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6"357.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES382 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish382 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish384.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish385 ft. AMH - Downstream Manhole, Survey Ends - 18 0083

Observation photos (6)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    88.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    144.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    167.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    202.4 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    357.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (24)

DistanceCodeObservation
384.7SAV
256.4RFJ
0MGOROACHES @ MH
202.4FL
144.9FL
382DAGS
343.7TFA
87.7TFA
157.3TFA
167.1FM
357.1FM
86TFC
382SSS
276.6TFA
2DAGS
0MWM
2SAV
0MWL
296.4RFJ
2SSS
0AMH18 0084
385AMH18 0083
88.9FL
8.7TFA

Properties (7)

additional_info
630074050422201
custom_field_three
AGGREGATE VISIBLE/FRACTURE'S
custom_field_two
3
customer
1
datetime
2022-05-04T23:15:58-07:00
documentation
PROPIPE
is_lateral_inspection
false