- Date
- 05/04/2022
- W/O
- 952101
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00698
- PipeID
- P13903
- Time
- 11:15 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10089
- Sewer Name
- 18 SANTA FE STREET TRUNK
- City
- WHITTIER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_952101_TV18177_MAY2022
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 18 0084
- Downstream MH
- 18 0083
- Dir. of Survey
- Downstream
- Length Surveyed
- 385 ft.
- Total Length
- 385 ft.
- Structural Index
- 3
- Structural Quick
- 423O
- Structural Rating
- 400
- O&M Index
- 2
- O&M Quick
- 2N12
- O&M Rating
- 154
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 554
Pipe schematic from manhole 18 0084 to 18 0083 Observation photos (6)

2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

88.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

144.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

167.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

202.4 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

357.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES