- Date
- 05/03/2022
- W/O
- 952101
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00698
- PipeID
- P13897
- Time
- 3:02 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10088
- Sewer Name
- 18 SANTA FE STREET TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_952101_TV18177_MAY2022
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 18 0078
- Downstream MH
- 18 0079
- Dir. of Survey
- Upstream
- Length Surveyed
- 296.4 ft.
- Total Length
- 296.4 ft.
- Structural Index
- 3
- Structural Quick
- 3K2K
- Structural Rating
- 290
- O&M Index
- 2
- O&M Quick
- 2K00
- O&M Rating
- 116
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 406
Pipe schematic from manhole 18 0078 to 18 0079 Observation photos (2)

2.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start