Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 3, 2022, 09:08 AM
  • 02 0366A_02 0366_05032022_032601.mp4

Date
05/03/2022
W/O
951851
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00250
PipeID
P02681
Time
2:08 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10044
Sewer Name
02 DOWNEY AVENUE EXTENSION TRUNK
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_951851_TV02126_MAY2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 0366A
Downstream MH
02 0366
Dir. of Survey
Downstream
Length Surveyed
300.3 ft.
Total Length
300.3 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
165
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
167
Pipe schematic from manhole 02 0366A to 02 0366
MH: 02 0366AMH: 02 0366downstream0 ft. MGO - General Observation - ROACHES @ MH0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 0366A15 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6" - SADDLE CONN21.6 ft. TBB - Tap Break-In Abandoned, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6"23.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start64.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"76 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"111.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN126.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN161.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN172 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - UNKNOWN212.4 ft. TFI - Tap Factory Made Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 4", 1", 6" - OFFSET CONN/ACTIVE227.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"262.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN273.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"298.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish300.3 ft. MGO - General Observation - ROACHES @ MH300.3 ft. AMH - Downstream Manhole, Survey Ends - 02 0366

Observation photos (3)

  • General Observation - ROACHES @ MH

    0 ft. - General Observation - ROACHES @ MH

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    23.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - ROACHES @ MH

    300.3 ft. - General Observation - ROACHES @ MH

Observations (21)

DistanceCodeObservation
0MGOROACHES @ MH
15TBASADDLE CONN
172TFUNKNOWN
300.3MGOROACHES @ MH
21.6TBB
76TFC
126.8TFOPEN
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
0MWL
262.7TFOPEN
23.2CM
298.7CM
111.4TFOPEN
300.3AMH02 0366
0MWM
64.7TFC
161.8TFOPEN
273.6TFC
227.7TFC
0AMH02 0366A
212.4TFIOFFSET CONN/ACTIVE

Properties (7)

additional_info
630063050222201
custom_field_three
CRACKS
custom_field_two
2
customer
1
datetime
2022-05-03T02:08:33-07:00
documentation
PRO PIPE
is_lateral_inspection
false