Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 6, 2022, 07:33 AM
  • 22 1466_22 0672A_05062022_014430.mp4

Date
05/06/2022
W/O
951982
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00827
PipeID
P27149
Time
12:33 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10049
Sewer Name
22 SUNFLOWER TRUNK
City
SAN DIMAS
Loc. details
Light Highway
Location Code
C
District
District 22
Page No.
22
Purpose
Routine Assessment
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Other
Height
15 in.
Upstream MH
22 1466
Downstream MH
22 0672A
Dir. of Survey
Downstream
Length Surveyed
138 ft.
Total Length
138 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2D00
O&M Rating
54
Overall Index
2
Overall Quick
Overall Rating
54
Pipe schematic from manhole 22 1466 to 22 0672A
MH: 22 1466MH: 22 0672Adownstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 14660 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start6.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"9.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"21.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"86.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"92.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"124.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"135.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish138 ft. MGO - General Observation - COCKROACHES AT MH138 ft. MGO - General Observation - CONNECTION AT MH 12 O'CLOCK138 ft. AMH - Downstream Manhole, Survey Ends - 22 0672A

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES AT MH

    138 ft. - General Observation - COCKROACHES AT MH

Observations (14)

DistanceCodeObservation
138MGOCOCKROACHES AT MH
0MWL
124.5TFA
135.8DAGS
86.4TFA
2DAGS
92.7TFA
6.6TF
138MGOCONNECTION AT MH 12 O'CLOCK
0AMH22 1466
21.9TFA
0MWM
9.2TFA
138AMH22 0672A

Properties (8)

additional_info
630063050522202
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2022-05-06T00:33:27-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
44232