- Date
- 05/13/2022
- W/O
- 0951647
- Weather
- Dry
- Operator/Surveyor
- REVELES
- Sewer ID
- Z00094
- PipeID
- P08996
- Time
- 3:55 AM
- Certificate
- U-115-06022630
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H3094R
- Sewer Name
- B JOINT OUTFALL B - UNIT 5D
- City
- ALTADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 06
- Purpose
- Resurvey For Any Reason
- Project
- 05132022VMR_JOINT_OUTFALL_B_UNIT_5_D
- Material
- NRCP
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- 16 0472
- Downstream MH
- 16 0471
- Dir. of Survey
- Downstream
- Length Surveyed
- 330.7 ft.
- Total Length
- 330.7 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2111
- O&M Rating
- 3
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 3
Pipe schematic from manhole 16 0472 to 16 0471 Observation photos (2)

12.1 ft. - Roots Fine Joint, from 10 to 05 o'clock, within 8 inches of joint: YESR - 5%

61.1 ft. - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 4", 5" - Open