Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 13, 2022, 05:26 AM
  • 22 0503_22 0502_04122022_224435.mp4

Date
04/12/2022
W/O
946708
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00800
PipeID
P16842
Time
10:26 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9962
Sewer Name
22 COVINA CONNECTION EXTENSION TRUNK
City
COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
RFIR_WO_946708_TV22031_APR2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
22 0502
Downstream MH
22 0503
Dir. of Survey
Upstream
Length Surveyed
326.1 ft.
Total Length
326.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 22 0502 to 22 0503
MH: 22 0502MH: 22 0503upstream0 ft. AMH - Upstream Manhole, Survey Ends - 22 05030 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish40.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"44 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"88.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"91.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"139.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"142.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"190.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"193.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"238.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"241.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"289.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"292.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"301.2 ft. MGO - General Observation - MAG COAT323.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start326.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK326.1 ft. MWL - Water Level, 10 %of cross sectional area326.1 ft. MWM - Water Mark, 10 %of cross sectional area326.1 ft. AMH - Downstream Manhole, Survey Begins - 22 0502

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (21)

DistanceCodeObservation
2.2SAP
326.1AMH22 0503
0MGOCONNECTION AT MH 9 O'CLOCK
87.4TFC
0MWL
234.3TFC
285.2TFC
132.6TFC
326.1MGOCONNECTION AT MH 9 O'CLOCK
237.2TFC
33.9TFC
84.7TFC
36.6TFC
135.4TFC
24.9MGOMAG COAT
282.1TFC
183.4TFC
325.1SAP
186.3TFC
0MWM
0AMH22 0502

Properties (7)

additional_info
630138041222201
custom_field_three
AGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2022-04-12T22:26:51-07:00
documentation
PRO PIPE
is_lateral_inspection
false