Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 15, 2022, 10:12 AM
  • 15 1099_15 1098_04152022_032407.mp4

Date
04/15/2022
W/O
947050
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00614
PipeID
P12859
Time
3:12 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9968
Sewer Name
15 MERCED TRUNK, SECTION 1
City
S EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
RFIR_WO_947050_TV15099_APR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 1099
Downstream MH
15 1098
Dir. of Survey
Downstream
Length Surveyed
299.1 ft.
Total Length
299.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 15 1099 to 15 1098
MH: 15 1099MH: 15 1098downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 10990 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start7.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"20.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"81.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"191.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"243.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"249.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"299.1 ft. AMH - Downstream Manhole, Survey Ends - 15 1098299.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
299.1AMH15 1098
20.3TF
2DAGS
243.2TF
7.8TF
0AMH15 1099
191.1TF
249.8TF
0MWM
81.6TFA
0MWL
299.1DAGS

Properties (7)

additional_info
630138041422203
custom_field_three
NO STRUCTURAL DEFECTS
custom_field_two
4
customer
1
datetime
2022-04-15T03:12:36-07:00
documentation
PRO PIPE
is_lateral_inspection
false