Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 18, 2022, 09:58 AM
  • 15 1093_15 1092_04182022_031139.mp4

Date
04/18/2022
W/O
947050
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00614
PipeID
P12853
Time
2:58 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10072
Sewer Name
15 MERCED TRUNK, SECTION 1
City
S EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
RFIR_WO_947050_TV15099_APR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 1092
Downstream MH
15 1093
Dir. of Survey
Upstream
Length Surveyed
103.7 ft.
Total Length
103.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 15 1092 to 15 1093
MH: 15 1092MH: 15 1093upstream0 ft. MSA - Survey Abandoned - CAM BLKD OBJECT IN JOINT0.3 ft. OBZ - Obstacles Other, 20 %of cross sectional area, from 12 to 06 o'clock15.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"58.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"103.7 ft. MWM - Water Mark, 15 %of cross sectional area103.7 ft. AMH - Downstream Manhole, Survey Begins - 15 1092103.7 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (2)

  • Obstacles Other, 20 %of cross sectional area, from 12 to 06 o'clock

    103.4 ft. - Obstacles Other, 20 %of cross sectional area, from 12 to 06 o'clock

  • Survey Abandoned - CAM BLKD OBJECT IN JOINT

    103.7 ft. - Survey Abandoned - CAM BLKD OBJECT IN JOINT

Observations (7)

DistanceCodeObservation
103.4OBZ
103.7MSACAM BLKD OBJECT IN JOINT
45TF
0MWM
88TFC
0AMH15 1092
0MWL

Properties (6)

additional_info
630074041822001
custom_field_two
5
customer
1
datetime
2022-04-18T02:58:28-07:00
documentation
PRO PIPE
is_lateral_inspection
false