Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 18, 2022, 12:09 PM
  • 15 0438_15 0437_04182022_052520.mp4

Date
04/18/2022
W/O
947219
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00625
PipeID
P12364
Time
5:09 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10073
Sewer Name
15 RIVER AVENUE TRUNK
City
S EL MONTE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
27
Purpose
Routine Assessment
Project
RFIR_WO_947219_TV15246_APR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0438
Downstream MH
15 0437
Dir. of Survey
Downstream
Length Surveyed
425.1 ft.
Total Length
425.1 ft.
Structural Index
2
Structural Quick
4131
Structural Rating
12
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
12
Pipe schematic from manhole 15 0438 to 15 0437
MH: 15 0438MH: 15 0437downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 043828.5 ft. FM - Fracture Multiple, from 07 to 08 o'clock, within 8 inches of joint: YES302.4 ft. CM - Crack Multiple, from 03 to 05 o'clock, within 8 inches of joint: YES333.1 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES337.8 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES423.3 ft. CC - Crack Circumferential, from 12 to 12 o'clock, within 8 inches of joint: YES425.1 ft. AMH - Downstream Manhole, Survey Ends - 15 0437

Observation photos (5)

  • Fracture Multiple, from 07 to 08 o'clock, within 8 inches of joint: YES

    28.5 ft. - Fracture Multiple, from 07 to 08 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 03 to 05 o'clock, within 8 inches of joint: YES

    302.4 ft. - Crack Multiple, from 03 to 05 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    333.1 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    337.8 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 12 to 12 o'clock, within 8 inches of joint: YES

    423.3 ft. - Crack Circumferential, from 12 to 12 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
0MWM
333.1CL
0MWL
425.1AMH15 0437
28.5FM
0AMH15 0438
302.4CM
423.3CC
337.8CL

Properties (7)

additional_info
630074041822002
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-04-18T05:09:16-07:00
documentation
PROPIPE
is_lateral_inspection