Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 22, 2022, 02:52 PM
  • 01 1184_01 1183_04062022_023309.mp4

Date
03/22/2022
W/O
946843
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00225
PipeID
P02038
Time
7:52 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9792
Sewer Name
01 WILCOX AVENUE TRUNK
City
BELL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
05
Purpose
Routine Assessment
Project
WO_946843_TV01072_APR2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
21 in.
Upstream MH
01 1184
Downstream MH
01 1183
Dir. of Survey
Downstream
Length Surveyed
299.1 ft.
Total Length
299.1 ft.
Structural Index
3
Structural Quick
3K21
Structural Rating
188
O&M Index
2
O&M Quick
412T
O&M Rating
218
Overall Index
2
Overall Quick
Overall Rating
406
Pipe schematic from manhole 01 1184 to 01 1183
MH: 01 1184MH: 01 1183downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 01 11842 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. MGO - General Observation - MAG COATING2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start54.9 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - UNDER FLOW55.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"58.7 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"70.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"98.3 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"108.1 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"130.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"147.7 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"155.5 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"190.4 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"227.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES227.9 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"257.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"258.8 ft. FS - Fracture Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES259.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"288 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 4"290.6 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"293.3 ft. FS - Fracture Spiral, from 12 to 01 o'clock, within 8 inches of joint: YES295.6 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: NO296.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish296.8 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish296.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish299.1 ft. AMH - Downstream Manhole, Survey Ends - 01 1183

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    227.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES

    258.8 ft. - Fracture Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 12 to 01 o'clock, within 8 inches of joint: YES

    293.3 ft. - Fracture Spiral, from 12 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: NO

    295.6 ft. - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: NO

Observations (31)

DistanceCodeObservation
155.5TF
290.6TF
257.8TFC
58.7TF
54.9DSCUNDER FLOW
0MGOCONNECTION AT THE MH 3 OC'LOCK
147.7TFA
0MWM
70.7TF
2DAGS
0MWL
288TF
296.8DAGS
258.8FS
108.1TF
0MGOCONNECTION AT THE MH 9 OC'LOCK
259.9TFA
0AMH01 1184
2MGOMAG COATING
190.4TF
296.8DSC
299.1AMH01 1183
2SAP
98.3TF
227.1CM
130.4TF
55.7TF
295.6FC
293.3FS
296.8SAP
227.9TF

Properties (7)

additional_info
6300630406222021
custom_field_three
FRACTURES, AGGREGATE PROJECTING
custom_field_two
2
customer
1
datetime
2022-03-22T07:52:44-07:00
documentation
PROPIPE
is_lateral_inspection
false