Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 22, 2022, 09:22 AM
  • 15 1119_15 1118_03222022_023504.mp4

Date
03/22/2022
W/O
941337
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00615
PipeID
P12879
Time
2:22 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9932
Sewer Name
15 MERCED TRUNK, SECTION 2
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
RFIR_WO_941337_TV15100_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 1119
Downstream MH
15 1118
Dir. of Survey
Downstream
Length Surveyed
228 ft.
Total Length
228 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 1119 to 15 1118
MH: 15 1119MH: 15 1118downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 11190 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK8.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"66.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"92 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"93.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"125.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"171.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"193.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"217.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"221.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"228 ft. AMH - Downstream Manhole, Survey Ends - 15 1118

Observation photos (1)

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    171.5 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (14)

DistanceCodeObservation
221.8TFC
171.5TB
228AMH15 1118
93.2TF
66.1TF
8.2TF
92TF
0MWM
217.4TF
193.4TF
0MWL
125.5TFC
0AMH15 1119
0MGOCONNECTION AT THE MH 9 OC'LOCK

Properties (7)

additional_info
630074032122203
custom_field_three
RFIR NO SEVERE DEFECTS
custom_field_two
3
customer
1
datetime
2022-03-22T02:22:34-07:00
documentation
PROPIPE
is_lateral_inspection
false