Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 22, 2022, 09:35 AM
  • 15 1118_15 1117_03222022_024558.mp4

Date
03/22/2022
W/O
941337
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00615
PipeID
P12878
Time
2:35 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9932
Sewer Name
15 MERCED TRUNK, SECTION 2
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
RFIR_WO_941337_TV15100_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 1118
Downstream MH
15 1117
Dir. of Survey
Downstream
Length Surveyed
210.1 ft.
Total Length
210.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 1118 to 15 1117
MH: 15 1118MH: 15 1117downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 11186.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"8 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"18.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"58.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"107 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"124.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"133.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"205.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"210.1 ft. AMH - Downstream Manhole, Survey Ends - 15 1117210.1 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK

Observation photos (1)

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    133.7 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (13)

DistanceCodeObservation
205.8TF
58.1TF
8TB
210.1AMH15 1117
107TF
18.8TF
0MWL
133.7TB
124.7TF
210.1MGOCONNECTION AT THE MH 9 OC'LOCK
6.3TB
0MWM
0AMH15 1118

Properties (7)

additional_info
630074032122203
custom_field_three
RFIR NO SEVERE DEFECTS
custom_field_two
3
customer
1
datetime
2022-03-22T02:35:49-07:00
documentation
PROPIPE
is_lateral_inspection
false