- Date
- 04/11/2022
- W/O
- 946718
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00171
- PipeID
- P10636
- Time
- 9:48 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10058
- Sewer Name
- H JOINT OUTFALL H - UNIT 2F
- City
- COMMERCE
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- RFIR_WO_946718_TV02361_APR2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- H 0219
- Downstream MH
- A 1223
- Dir. of Survey
- Downstream
- Length Surveyed
- 291.9 ft.
- Total Length
- 291.9 ft.
- Structural Index
- 3
- Structural Quick
- 3K00
- Structural Rating
- 174
- O&M Index
- 2
- O&M Quick
- 2K00
- O&M Rating
- 118
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 292
Pipe schematic from manhole H 0219 to A 1223 Observation photos (2)

2.1 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start