Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 13, 2022, 07:11 AM
  • 05 0947_05 0125_04132022_003117.mp4

Date
04/13/2022
W/O
946719
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00481
PipeID
P06179
Time
12:11 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10065
Sewer Name
05 MANCHESTER AVENUE PUMP TRUNK
City
HAWTHRONE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_946719_TV05335_APR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
15 in.
Upstream MH
05 0947
Downstream MH
05 0125
Dir. of Survey
Downstream
Length Surveyed
436.7 ft.
Total Length
436.7 ft.
Structural Index
3
Structural Quick
3P22
Structural Rating
253
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
253
Pipe schematic from manhole 05 0947 to 05 0125
MH: 05 0947MH: 05 0125downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 09470 ft. MWM - Water Mark, 40 %of cross sectional area3.6 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES12.6 ft. CS - Crack Spiral, from 12 to 04 o'clock, within 8 inches of joint: YES21.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start30.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"77.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"129.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"178.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"231 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"279.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"328.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"380.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"435.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish436.7 ft. AMH - Downstream Manhole, Survey Ends - 05 0125436.7 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK

Observation photos (3)

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    3.6 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 12 to 04 o'clock, within 8 inches of joint: YES

    12.6 ft. - Crack Spiral, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    21.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
0MWL
3.6CL
77.9TFC
129.6TFC
178.3TFC
435.1CM
12.6CS
0AMH05 0947
279.8TFC
380.5TFC
436.7AMH05 0125
231TFC
436.7MGOCONNECTION AT THE MH 3 OC'LOCK
328.9TFC
21.5CM
30.8TFC
0MWM

Properties (7)

additional_info
630074041222203
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-04-13T00:11:25-07:00
documentation
PROPIPE
is_lateral_inspection
false