Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 12, 2022, 07:26 AM
  • 02 0947A_H 0188_04122022_003316.mp4

Date
04/12/2022
W/O
946709
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00279
PipeID
P04585
Time
12:26 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10059
Sewer Name
02 MONTEBELLO TRUNK
City
BELL GARDENS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
23
Purpose
Routine Assessment
Project
RFIR_WO_946709_TV02334_APR2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
02 0947A
Downstream MH
H 0188
Dir. of Survey
Downstream
Length Surveyed
121.4 ft.
Total Length
121.4 ft.
Structural Index
3
Structural Quick
3D2A
Structural Rating
96
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
96
Pipe schematic from manhole 02 0947A to H 0188
MH: 02 0947AMH: H 0188downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 0947A0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - MAG COAT42.5 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"63.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start121.4 ft. AMH - Downstream Manhole, Survey Ends - H 0188121.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish121.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish121.4 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK

Observation photos (3)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    42.5 ft. - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    63.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0MWM
121.4AMHH 0188
63.4SSS
2.1SAV
121.4SSS
0AMH02 0947A
0MWL
0MGOCONNECTION AT THE MH 9 OC'LOCK
121.4SAV
2.1MGOMAG COAT
121.4MGOCONNECTION AT THE MH 3 OC'LOCK
42.5TS

Properties (7)

additional_info
630074041122202
custom_field_three
AGGREGATE VISIBLE/SPALLING
custom_field_two
3
customer
1
datetime
2022-04-12T00:26:12-07:00
documentation
PROPIPE
is_lateral_inspection
false