Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 11, 2022, 10:14 AM
  • 02 0994_02 0993_04112022_032734.mp4

Date
04/11/2022
W/O
946709
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00279
PipeID
P03566
Time
3:14 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10057
Sewer Name
02 MONTEBELLO TRUNK
City
COMMERCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
18
Purpose
Routine Assessment
Project
RFIR_WO_946709_TV02334_APR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
15 in.
Upstream MH
02 0994
Downstream MH
02 0993
Dir. of Survey
Downstream
Length Surveyed
172.2 ft.
Total Length
172.2 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
93
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
93
Pipe schematic from manhole 02 0994 to 02 0993
MH: 02 0994MH: 02 0993downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 09940 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area15.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start109 ft. MGO - General Observation - ABANDONED MH167.6 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"172.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish172.2 ft. AMH - Downstream Manhole, Survey Ends - 02 0993

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    15.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    167.6 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

Observations (8)

DistanceCodeObservation
167.6TB
0AMH02 0994
172.2CM
0MWL
0MWM
172.2AMH02 0993
109MGOABANDONED MH
15.5CM

Properties (7)

additional_info
630074041122003
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2022-04-11T03:14:01-07:00
documentation
PROPIPE
is_lateral_inspection
false