Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 11, 2022, 11:11 AM
  • 02 0981_02 0980_04112022_042412.mp4

Date
04/11/2022
W/O
946709
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00279
PipeID
P03556
Time
4:11 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10057
Sewer Name
02 MONTEBELLO TRUNK
City
COMMERCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_946709_TV02334_APR2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
15 in.
Upstream MH
02 0981
Downstream MH
02 0980
Dir. of Survey
Downstream
Length Surveyed
374.6 ft.
Total Length
374.6 ft.
Structural Index
3
Structural Quick
3N2N
Structural Rating
368
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
368
Pipe schematic from manhole 02 0981 to 02 0980
MH: 02 0981MH: 02 0980downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 09812.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start370 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish374.6 ft. AMH - Downstream Manhole, Survey Ends - 02 0980374.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWM
2.2SAV
374.6AMH02 0980
0MWL
370SSS
374.6SAV
0AMH02 0981
4SSS

Properties (7)

additional_info
630074041122003
custom_field_three
MULTIPLE CRACKS/SPALLING
custom_field_two
3
customer
1
datetime
2022-04-11T04:11:53-07:00
documentation
PROPIPE
is_lateral_inspection
false