Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 24, 2022, 08:42 AM
  • 15 0951_15 0143_03242022_015553.mp4

Date
03/24/2022
W/O
941456
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00634
PipeID
P12044
Time
1:42 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10017
Sewer Name
15 TYLER AVENUE TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
23
Purpose
Routine Assessment
Project
WO_941456_TV15037_MAR2022
Sewer Type
Gravity
Material
NRCP
Shape
Square
Height
15 in.
Width
15 in.
Upstream MH
15 0143
Downstream MH
15 0951
Dir. of Survey
Upstream
Length Surveyed
334.5 ft.
Total Length
334.5 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2L00
O&M Rating
132
Overall Index
2
Overall Quick
Overall Rating
138
Pipe schematic from manhole 15 0143 to 15 0951
MH: 15 0143MH: 15 0951upstream0 ft. AMH - Upstream Manhole, Survey Ends - 15 09510 ft. MGO - General Observation - CONNECTION AT MH 9, 12 O'CLOCK0 ft. MGO - General Observation - COCKROACHES IN MH1.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish1.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish11.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start163.4 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"197.6 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"321.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"332.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start332.5 ft. MGO - General Observation - MAG COAT334.5 ft. AMH - Downstream Manhole, Survey Begins - 15 0143334.5 ft. MGO - General Observation - COCKROACHES IN MH334.5 ft. MWM - Water Mark, 15 %of cross sectional area334.5 ft. MWL - Water Level, 5 %of cross sectional area334.5 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (5)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - MAG COAT

    2 ft. - General Observation - MAG COAT

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    322.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MH

    334.5 ft. - General Observation - COCKROACHES IN MH

Observations (16)

DistanceCodeObservation
136.9TFA
171.1TFA
322.6SAP
2DAGS
0AMH15 0143
12.8TFA
0MGOCOCKROACHES IN MH
334.5AMH15 0951
334.5MGOCONNECTION AT MH 9, 12 O'CLOCK
2MGOMAG COAT
0MWM
333.4DAGS
334.5MGOCOCKROACHES IN MH
0MWL
0MGOCONNECTION AT MH 3 O'CLOCK
333.4SAP

Properties (7)

additional_info
630138032322201
custom_field_three
PROJECTING AGGREGATE
custom_field_two
3
customer
1
datetime
2022-03-24T01:42:22-07:00
documentation
PRO PIPE
is_lateral_inspection
false