Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 24, 2022, 05:06 AM
  • 15 0110_H 0445_03232022_221724.mp4

Date
03/23/2022
W/O
941456
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00634
PipeID
P12007
Time
10:06 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10017
Sewer Name
15 TYLER AVENUE TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
WO_941456_TV15037_MAR2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0110
Downstream MH
H 0445
Dir. of Survey
Downstream
Length Surveyed
260.2 ft.
Total Length
260.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0110 to H 0445
MH: 15 0110MH: H 0445downstream0 ft. MGO - General Observation - MAG COAT0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. AMH - Upstream Manhole, Survey Begins - 15 01100 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area7.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"10.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"59 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"62 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"107.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"110.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"159.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"163.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"208.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"211.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"260.2 ft. MGO - General Observation - COCKROACHES IN MH260.2 ft. AMH - Downstream Manhole, Survey Ends - H 0445260.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (3)

  • General Observation - MAG COAT

    0 ft. - General Observation - MAG COAT

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • General Observation - COCKROACHES IN MH

    260.2 ft. - General Observation - COCKROACHES IN MH

Observations (19)

DistanceCodeObservation
260.2MGOCOCKROACHES IN MH
159.9TFC
260.2AMHH 0445
0MGOMAG COAT
59TFC
211.6TFA
10.4TFC
0MWL
208.5TFC
0MGOCOCKROACHES IN MH
7.1TFC
107.4TFC
62TFC
0AMH15 0110
163.2TFC
0MGOCONNECTION AT MH 9 O'CLOCK
110.4TFC
260.2MGOCONNECTION AT MH 9 O'CLOCK
0MWM

Properties (5)

additional_info
630138032322201
customer
1
datetime
2022-03-23T22:06:26-07:00
documentation
PRO PIPE
is_lateral_inspection
false