Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 23, 2022, 10:26 AM
  • 15 0123_15 0122_03232022_033357.mp4

Date
03/23/2022
W/O
941456
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00634
PipeID
P12021
Time
3:26 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10016
Sewer Name
15 TYLER AVENUE TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
23
Purpose
Routine Assessment
Project
WO_941456_TV15037_MAR2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0122
Downstream MH
15 0123
Dir. of Survey
Upstream
Length Surveyed
130.4 ft.
Total Length
130.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 15 0122 to 15 0123
MH: 15 0122MH: 15 0123upstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - 15 01230 ft. MGO - General Observation - COCKROACHES IN MH1.8 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish5.1 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start35.9 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"111.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"123.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"128.4 ft. MGO - General Observation - MAG COAT130.4 ft. MWL - Water Level, 5 %of cross sectional area130.4 ft. MWM - Water Mark, 10 %of cross sectional area130.4 ft. AMH - Downstream Manhole, Survey Begins - 15 0122

Observation photos (2)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    125.3 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MH

    130.4 ft. - General Observation - COCKROACHES IN MH

Observations (12)

DistanceCodeObservation
18.6TFC
128.6SAP
130.4MGOCONNECTION AT MH 3 O'CLOCK
125.3SAP
94.5TF
2MGOMAG COAT
130.4AMH15 0123
130.4MGOCOCKROACHES IN MH
0MWL
6.5TFC
0MWM
0AMH15 0122

Properties (5)

additional_info
630138032222201
customer
1
datetime
2022-03-23T03:26:28-07:00
documentation
PRO PIPE
is_lateral_inspection
false