- Date
- 04/28/2022
- W/O
- 953677
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00744
- PipeID
- P19050
- Time
- 2:47 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10083
- Sewer Name
- 20 TRUNK "C"
- City
- PALMDALE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 20
- Page No.
- 01
- Purpose
- Routine Assessment
- Project
- URGENT_WO_953677_2022
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 20 0126
- Downstream MH
- 20 0126A
- Dir. of Survey
- Upstream
- Length Surveyed
- 27.5 ft.
- Total Length
- 27.5 ft.
- Structural Index
- 3
- Structural Quick
- 3525
- Structural Rating
- 25
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 29
Pipe schematic from manhole 20 0126 to 20 0126A Observation photos (4)

2.1 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

2.1 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

27.5 ft. - Obstacles Pipe Material, 25 %of cross sectional area, from 07 to 05 o'clock

27.5 ft. - Survey Abandoned - CAM BLKD BY DEBRIS 25%