Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 14, 2022, 08:41 AM
  • E 0209_01 0053A_04142022_015156.mp4

Date
04/14/2022
W/O
946705
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00209
PipeID
P02146
Time
1:41 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10069
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
LOS ANGELES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_946705_TV01254_APR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
01 0053A
Downstream MH
E 0209
Dir. of Survey
Upstream
Length Surveyed
157.5 ft.
Total Length
157.5 ft.
Structural Index
3
Structural Quick
514E
Structural Rating
280
O&M Index
2
O&M Quick
2E00
O&M Rating
62
Overall Index
3
Overall Quick
Overall Rating
342
Pipe schematic from manhole 01 0053A to E 0209
MH: 01 0053AMH: E 0209upstream0 ft. AMH - Upstream Manhole, Survey Ends - E 02090.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish86.4 ft. B - Broken, from 07 to 10 o'clock, within 8 inches of joint: YES90.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"92 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"141.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"143.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"148.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start155.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start155.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start155.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start157.5 ft. MWM - Water Mark, 10 %of cross sectional area157.5 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE157.5 ft. MWL - Water Level, 5 %of cross sectional area157.5 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/UNKNOWN157.5 ft. AMH - Downstream Manhole, Survey Begins - 01 0053A

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
16.1TFC
155CM
2DAGS
155DAGS
0MWM
157.5AMHE 0209
157.2FM
13.6TFC
155SSS
67.4TFC
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
0MWL
0MGOCONN @ MH 3 O'CLOCK/UNKNOWN
2SSS
65.5TFC
8.8FM
2CM
71.1B
0AMH01 0053A

Properties (7)

additional_info
630078041322202
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2022-04-14T01:41:55-07:00
documentation
PROPIPE
is_lateral_inspection
false