- Date
- 04/21/2022
- W/O
- 946716
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00782
- PipeID
- P23207
- Time
- 8:55 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9796
- Sewer Name
- 21 POMONA W.R.P. INFLUENT SEWER #2
- City
- POMONA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- RFIR_WO_946716_TV21100_APR2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Upstream MH
- 21 1268
- Downstream MH
- 21 1267
- Dir. of Survey
- Downstream
- Length Surveyed
- 73.6 ft.
- Total Length
- 73.6 ft.
- Structural Index
- 2
- Structural Quick
- 5131
- Structural Rating
- 36
- O&M Index
- 2
- O&M Quick
- 2B00
- O&M Rating
- 28
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 64
Pipe schematic from manhole 21 1268 to 21 1267 Observation photos (4)

2.6 ft. - Alignment Right, 15 %, Start

2.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

71.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES

71.1 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO