Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 14, 2022, 11:35 AM
  • 17 0006_17 0005_4142022_043735.mp4

Date
04/14/2022
W/O
0946948
Weather
Dry
Operator/Surveyor
REVELES, IGNACIO
Sewer ID
Z00668
PipeID
P13731
Time
4:35 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
H3064
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
07
Purpose
Routine Assessment
Project
200414VMR_DISTRICT_17_MAIN_TRUCK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
17 0006
Downstream MH
17 0005
Dir. of Survey
Downstream
Length Surveyed
317.7 ft.
Total Length
317.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 17 0006 to 17 0005
MH: 17 0006MH: 17 0005downstream0 ft. AMH - Upstream Manhole, Survey Begins - 04:26 AM0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area317.7 ft. AMH - Downstream Manhole, Survey Ends - 04:45AM

Observations (4)

DistanceCodeObservation
0AMH04:26 AM
0MWM
317.7AMH04:45AM
0MWL

Properties (4)

customer
LACSD
datetime
2022-04-14T04:35:02-07:00
documentation
REVELES, IGNACIO
is_lateral_inspection
false