Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 15, 2022, 08:24 AM
  • A 0639_A 0638_02152022_005454.mp4

Date
02/15/2022
W/O
936573
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00316
PipeID
P07844
Time
12:24 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9782
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
34
Purpose
Routine Assessment
Project
WO_936573_TV21027_FEB2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
45 in.
Width
54 in.
Upstream MH
A 0639
Downstream MH
A 0638
Dir. of Survey
Downstream
Length Surveyed
979.3 ft.
Total Length
979.3 ft.
Structural Index
2
Structural Quick
312f
Structural Rating
393
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
393
Pipe schematic from manhole A 0639 to A 0638
MH: A 0639MH: A 0638downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 06390 ft. MWM - Water Mark, 35 %of cross sectional area2.3 ft. MGO - General Observation - MAG COATING5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start233.1 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 4"625.6 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6"695.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 4"841.2 ft. SSS - Surface Spalling, from 02 to 04 o'clock, within 8 inches of joint: NO942.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 4"958.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"975 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish976.4 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES - AT MOUTH OF PIPE979.3 ft. AMH - Downstream Manhole, Survey Ends - A 0638

Observation photos (2)

  • Surface Spalling, from 02 to 04 o'clock, within 8 inches of joint: NO

    841.2 ft. - Surface Spalling, from 02 to 04 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES - AT MOUTH OF PIPE

    976.4 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES - AT MOUTH OF PIPE

Observations (14)

DistanceCodeObservation
942.3TB
695.4TB
0MWL
2.3MGOMAG COATING
625.6TB
0AMHA 0639
979.3AMHA 0638
5SSS
976.4SAPAT MOUTH OF PIPE
841.2SSS
975SSS
0MWM
233.1TB
958.9TB

Properties (7)

additional_info
630098021422201
custom_field_three
AGGREGATE PROJECTING, SPALLING
custom_field_two
3
customer
1
datetime
2022-02-15T00:24:15-08:00
documentation
PROPIPE
is_lateral_inspection
false