Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 18, 2022, 02:59 PM
  • A 0646_A 0645B_02182022_073204.mp4

Date
02/18/2022
W/O
936573
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00316
PipeID
P26640
Time
6:59 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9907
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
34
Purpose
Routine Assessment
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Width
54 in.
Upstream MH
A 0646
Downstream MH
A 0645B
Dir. of Survey
Downstream
Length Surveyed
221.2 ft.
Total Length
221.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole A 0646 to A 0645B
MH: A 0646MH: A 0645Bdownstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 06462 ft. MGO - General Observation - MAG COATING6.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"221.2 ft. AMH - Downstream Manhole, Survey Ends - NON STRUCTURE NO MH A 0645B221.2 ft. MGO - General Observation - NON STRUCTURE

Observations (7)

DistanceCodeObservation
2MGOMAG COATING
0MWL
0MWM
6.8TF
221.2AMHNON STRUCTURE NO MH A 0645B
221.2MGONON STRUCTURE
0AMHA 0646

Properties (7)

additional_info
630098021822061
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2022-02-18T06:59:19-08:00
documentation
PROPIPE
is_lateral_inspection
false