Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 10, 2022, 05:54 PM
  • A 0666_A 0665_02102022_102013.mp4

Date
02/10/2022
W/O
936573
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00316
PipeID
P07875
Time
9:54 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9902
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
36
Purpose
Routine Assessment
Project
WO_936573_TV21027_FEB2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
A 0666
Downstream MH
A 0665
Dir. of Survey
Downstream
Length Surveyed
845.6 ft.
Total Length
845.6 ft.
Structural Index
2
Structural Quick
2`00
Structural Rating
332
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
332
Pipe schematic from manhole A 0666 to A 0665
MH: A 0666MH: A 0665downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 06662.1 ft. MGO - General Observation - MAG COATING THROUGHOUT10 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start261.3 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"769.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"840 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish845.6 ft. AMH - Downstream Manhole, Survey Ends - A 0665

Observations (10)

DistanceCodeObservation
769.2TF
840SSS
10SSS
845.6AMHA 0665
0MGOCONNECTION AT MH 3 O'CLOCK
0MWL
0MWM
261.3TFA
2.1MGOMAG COATING THROUGHOUT
0AMHA 0666

Properties (7)

additional_info
630098021022051
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2022-02-10T09:54:20-08:00
documentation
PROPIPE
is_lateral_inspection
false