Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 16, 2022, 08:42 PM
  • A 1047_A 0594_02162022_131132.mp4

Date
02/16/2022
W/O
936573
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00316
PipeID
P07800
Time
12:42 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9905
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
34
Purpose
Routine Assessment
Project
WO_936573_TV21027_FEB2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
24 in.
Upstream MH
A 1047
Downstream MH
A 0594
Dir. of Survey
Downstream
Length Surveyed
844.3 ft.
Total Length
844.3 ft.
Structural Index
3
Structural Quick
3W00
Structural Rating
360
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
360
Pipe schematic from manhole A 1047 to A 0594
MH: A 1047MH: A 0594downstream0 ft. AMH - Upstream Manhole, Survey Begins - A 10470 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. MGO - General Observation - MAG COATING94.9 ft. SAP - Surface Aggregate Projecting, from 09 to 10 o'clock, within 8 inches of joint: NO243.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start433.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"840.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish844.3 ft. AMH - Downstream Manhole, Survey Ends - A 0594

Observation photos (2)

  • Surface Aggregate Projecting, from 09 to 10 o'clock, within 8 inches of joint: NO

    94.9 ft. - Surface Aggregate Projecting, from 09 to 10 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    243.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

Observations (9)

DistanceCodeObservation
0AMHA 1047
243.5SAP
840.9SAP
2MGOMAG COATING
844.3AMHA 0594
94.9SAP
433.9TFA
0MWM
0MWL

Properties (7)

additional_info
630098021622051
custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2022-02-16T12:42:03-08:00
documentation
PROPIPE
is_lateral_inspection
false