Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 12, 2022, 10:58 AM
  • 01 0029_01 0028_04122022_040150.mp4

Date
04/12/2022
W/O
946704
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00209
PipeID
P00688
Time
3:58 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10062
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_946704_TV01245_APR2022
Sewer Type
Siphon
Material
CIP
Shape
Circular
Height
12 in.
Width
27 in.
Upstream MH
01 0028
Downstream MH
01 0029
Dir. of Survey
Upstream
Length Surveyed
2.2 ft.
Total Length
2.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
5
O&M Quick
5241
O&M Rating
14
Overall Index
5
Overall Quick
Overall Rating
14
Pipe schematic from manhole 01 0028 to 01 0029
MH: 01 0028MH: 01 0029upstream0 ft. MSA - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON0.1 ft. DAGS - Deposits Attached Grease, 40 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES0.1 ft. LU - Alignment Up, 45 %2.2 ft. AMH - Downstream Manhole, Survey Begins - 01 0028 S2.2 ft. MWM - Water Mark, 100 %of cross sectional area2.2 ft. MWL - Water Level, 100 %of cross sectional area

Observation photos (2)

  • Deposits Attached Grease, 40 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    2.1 ft. - Deposits Attached Grease, 40 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON

    2.2 ft. - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON

Observations (6)

DistanceCodeObservation
0AMH01 0028 S
2.2MSAVIEW OF UPLEG OF D/S SIPHON
0MWM
2.1DAGS
2.1LU
0MWL

Properties (9)

additional_info
630074041122205
custom_field_three
RFIR NO SEVERE DEFECTS/GREASE
custom_field_two
3
customer
1
datetime
2022-04-12T03:58:03-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP
year_laid
40524