Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 18, 2022, 07:13 AM
  • 01 0325A_01 0545_03182022_002223.mp4

Date
03/18/2022
W/O
941472
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00206
PipeID
P01034
Time
12:13 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10012
Sewer Name
01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
City
FLORENCE-GRAHAM
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_941472_TV01232_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
01 0325A
Downstream MH
01 0545
Dir. of Survey
Downstream
Length Surveyed
13.4 ft.
Total Length
13.4 ft.
Structural Index
3
Structural Quick
4132
Structural Rating
11
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
13
Pipe schematic from manhole 01 0325A to 01 0545
MH: 01 0325AMH: 01 0545downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 01 0325A0 ft. MGO - General Observation - COCKROACHES IN MH2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. MMC - Material Change, Vitrified clay pipe5.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES8.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES10.7 ft. CC - Crack Circumferential, from 12 to 12 o'clock, within 8 inches of joint: NO11.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish13.4 ft. AMH - Downstream Manhole, Survey Ends - 01 0545, RUN LIST STATES MH AT 20'13.4 ft. MGO - General Observation - COCKROACHES IN MH

Observation photos (8)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    2 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Material Change, Vitrified clay pipe

    2 ft. - Material Change, Vitrified clay pipe

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    5.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    8.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 12 to 12 o'clock, within 8 inches of joint: NO

    10.7 ft. - Crack Circumferential, from 12 to 12 o'clock, within 8 inches of joint: NO

  • General Observation - COCKROACHES IN MH

    13.4 ft. - General Observation - COCKROACHES IN MH

Observations (14)

DistanceCodeObservation
0MWL
0MWM
8.4CM
2FM
0MGOCONNECTION AT MH 9 O'CLOCK
10.7CC
11.8DAGS
13.4AMH01 0545, RUN LIST STATES MH AT 20'
5.5CM
2DAGS
13.4MGOCOCKROACHES IN MH
0AMH01 0325A
2MMC
0MGOCOCKROACHES IN MH

Properties (7)

additional_info
630138031722201
custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2022-03-18T00:13:40-07:00
documentation
PRO PIPE
is_lateral_inspection
false