Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 29, 2022, 06:41 AM
  • 15 1048_15 1047_03282022_235622.mp4

Date
03/28/2022
W/O
947049
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00631
PipeID
P12807
Time
11:41 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10022
Sewer Name
15 SLACK ROAD TRUNK
City
SOUTH EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
RFIR_WO_947049_TV15031_APR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 1048
Downstream MH
15 1047
Dir. of Survey
Downstream
Length Surveyed
331.1 ft.
Total Length
331.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3121
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 15 1048 to 15 1047
MH: 15 1048MH: 15 1047downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 10480 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MH2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start38.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"91.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"106.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"106.9 ft. RMC - Roots Medium Connection, from 01 to 05 o'clock, 20 %, within 8 inches of joint: NO127.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"172.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"176.4 ft. RFC - Roots Fine Connection, from 08 to 11 o'clock176.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"225.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"233.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"278.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"282 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"322.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"326.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"329 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish331.1 ft. MGO - General Observation - COCKROACHES IN MH331.1 ft. AMH - Downstream Manhole, Survey Ends - 15 1047

Observation photos (5)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Roots Medium Connection, from 01 to 05 o'clock, 20 %, within 8 inches of joint: NO

    106.9 ft. - Roots Medium Connection, from 01 to 05 o'clock, 20 %, within 8 inches of joint: NO

  • Roots Fine Connection, from 08 to 11 o'clock

    176.4 ft. - Roots Fine Connection, from 08 to 11 o'clock

  • General Observation - COCKROACHES IN MH

    331.1 ft. - General Observation - COCKROACHES IN MH

Observations (23)

DistanceCodeObservation
331.1MGOCOCKROACHES IN MH
106.9TFA
127.7TFC
176.4RFC
282TFA
233.5TFA
106.9RMC
0MGOCONNECTION AT MH 3 O'CLOCK
0MWL
91.4TFA
176.4TFA
322.6TFA
329DAGS
0AMH15 1048
0MWM
2DAGS
38.7TFA
225.1TFA
331.1AMH15 1047
172.3TFC
326.8TFA
278.2TFC
0MGOCOCKROACHES IN MH

Properties (7)

additional_info
630138032822201
custom_field_three
RFIR
custom_field_two
3
customer
1
datetime
2022-03-28T23:41:00-07:00
documentation
PRO PIPE
is_lateral_inspection
false