Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 5, 2022, 08:54 AM
  • 01 1223_01 1222_04052022_020402.mp4

Date
04/05/2022
W/O
947045
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00226
PipeID
P02137
Time
1:54 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10053
Sewer Name
01 WILCOX AVENUE TRUNK, EXTENSION #1
City
CUDAHY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_947045_TV01206_APR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
01 1222
Downstream MH
01 1223
Dir. of Survey
Upstream
Length Surveyed
270.8 ft.
Total Length
270.8 ft.
Structural Index
3
Structural Quick
413I
Structural Rating
160
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
160
Pipe schematic from manhole 01 1222 to 01 1223
MH: 01 1222MH: 01 1223upstream0 ft. AMH - Upstream Manhole, Survey Ends - 01 12230 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish10.2 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES54 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"56 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"210.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"212.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"259.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start270.8 ft. MWL - Water Level, 15 %of cross sectional area270.8 ft. MWM - Water Mark, 25 %of cross sectional area270.8 ft. AMH - Downstream Manhole, Survey Begins - 01 1222

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    10.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    260.6 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
260.6FM
214.8TFC
0MWL
270.8AMH01 1223
216.8TFC
10.9CM
270.8CM
58.6TFC
0MWM
0AMH01 1222
60.5TF

Properties (7)

additional_info
630074040422201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-04-05T01:54:32-07:00
documentation
PROPIPE
is_lateral_inspection
false