Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 5, 2022, 07:07 AM
  • 01 1211_01 1210_04052022_002127.mp4

Date
04/05/2022
W/O
947045
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00226
PipeID
P02123
Time
12:07 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10053
Sewer Name
01 WILCOX AVENUE TRUNK, EXTENSION #1
City
CUDAHY
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_947045_TV01206_APR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
01 1211
Downstream MH
01 1210
Dir. of Survey
Downstream
Length Surveyed
203.5 ft.
Total Length
203.5 ft.
Structural Index
3
Structural Quick
3B23
Structural Rating
45
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
45
Pipe schematic from manhole 01 1211 to 01 1210
MH: 01 1211MH: 01 1210downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 12110 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area17.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start81.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish136.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"147.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"159.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start176.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish203.5 ft. AMH - Downstream Manhole, Survey Ends - 01 1210

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    17.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    159.8 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0AMH01 1211
147.7TFC
81.1CM
159.8CL
17.9CM
0MWL
203.5AMH01 1210
136.5TFC
0MWM
176.2CL

Properties (7)

additional_info
630074040422201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-04-05T00:07:54-07:00
documentation
PROPIPE
is_lateral_inspection
false