Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 5, 2022, 04:33 AM
  • 01 1206_01 1205_04042022_220932.mp4

Date
04/04/2022
W/O
947045
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00226
PipeID
P02117
Time
9:33 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10053
Sewer Name
01 WILCOX AVENUE TRUNK, EXTENSION #1
City
CUDAHY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_947045_TV01206_APR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 1206
Downstream MH
01 1205
Dir. of Survey
Downstream
Length Surveyed
343.4 ft.
Total Length
343.4 ft.
Structural Index
3
Structural Quick
3724
Structural Rating
29
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
32
Pipe schematic from manhole 01 1206 to 01 1205
MH: 01 1206MH: 01 1205downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 12060 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area70 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"87.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"111.9 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"131.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES140.3 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES205.1 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES219.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"255.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"256.9 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES259.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES287.8 ft. CL - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES296.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start311.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish312.5 ft. TBI - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 6", 4"336.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES338.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES343.4 ft. AMH - Downstream Manhole, Survey Ends - 01 1205

Observation photos (11)

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    111.9 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    131.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    140.3 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

    205.1 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

    256.9 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    259.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    287.8 ft. - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    296.1 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 6", 4"

    312.5 ft. - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 6", 4"

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    336.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    338.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
343.4AMH01 1205
0AMH01 1206
219.4TFC
259.2FL
255.7TFC
256.9CL
287.8CL
336.5CM
0MWL
131.5CM
296.1FL
70TF
140.3CL
205.1CL
87.2TF
0MWM
111.9TB
311.8FL
312.5TBI
338.8CM

Properties (7)

additional_info
630074040422201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-04-04T21:33:35-07:00
documentation
PROPIPE
is_lateral_inspection
false