Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 5, 2022, 06:32 AM
  • 01 1201_01 1200_04042022_234520.mp4

Date
04/04/2022
W/O
947045
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00226
PipeID
P02112
Time
11:32 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10053
Sewer Name
01 WILCOX AVENUE TRUNK, EXTENSION #1
City
CUDAHY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_947045_TV01206_APR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 1201
Downstream MH
01 1200
Dir. of Survey
Downstream
Length Surveyed
310.2 ft.
Total Length
310.2 ft.
Structural Index
3
Structural Quick
3J21
Structural Rating
167
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
167
Pipe schematic from manhole 01 1201 to 01 1200
MH: 01 1201MH: 01 1200downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 120115.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"26.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES32 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start77 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"289.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish289.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start306 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish310.2 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK310.2 ft. AMH - Downstream Manhole, Survey Ends - 01 1200

Observation photos (3)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    26.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    32 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    289.7 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
306FL
26.1CL
0MWM
0MWL
310.2MGOCONNECTION AT THE MH 9 OC'LOCK
0AMH01 1201
289.6CM
32CM
289.7FL
77TFC
310.2AMH01 1200
15.7TFC

Properties (7)

additional_info
630074040422201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-04-04T23:32:31-07:00
documentation
PROPIPE
is_lateral_inspection
false