Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 7, 2021, 08:41 AM
  • 18 0665_18 0664_12072021_005136.mp4

Date
12/07/2021
W/O
921605
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00696
PipeID
P14514
Time
12:41 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9554
Sewer Name
18 PHOEBE AVENUE TRUNK
City
LA MIRADA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_921605_TV18081_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
18 0664
Downstream MH
18 0665
Dir. of Survey
Upstream
Length Surveyed
230.7 ft.
Total Length
230.7 ft.
Structural Index
4
Structural Quick
4A24
Structural Rating
56
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
56
Pipe schematic from manhole 18 0664 to 18 0665
MH: 18 0664MH: 18 0665upstream0 ft. MGO - General Observation - CONNECTION AT THE MH 12 OC'LOCK0 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 18 066561.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start85.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES110.8 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES121 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES132.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"137.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"155.6 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES218.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"223.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"230.7 ft. MWM - Water Mark, 15 %of cross sectional area230.7 ft. MWL - Water Level, 5 %of cross sectional area230.7 ft. AMH - Downstream Manhole, Survey Begins - 18 0664

Observation photos (5)

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    75.1 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    109.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    119.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    145 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    168.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
0MWM
119.9CL
98.3TFC
93.3TF
0MWL
230.7MGOCONNECTION AT THE MH 12 OC'LOCK
75.1CL
145CL
168.8FM
12.6TFC
230.7FM
7.3TFC
109.7CL
230.7AMH18 0665
0AMH18 0664

Properties (7)

additional_info
630074120621201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-12-07T00:41:48-08:00
documentation
PROPIPE
is_lateral_inspection
false