Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 22, 2022, 06:21 AM
  • 15 0103_15 0102_03212022_233731.mp4

Date
03/21/2022
W/O
941303
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00590
PipeID
P11981
Time
11:21 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9930
Sewer Name
15 ABBEY STREET TRUNK
City
LA PUENTE
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
38
Purpose
Routine Assessment
Project
RFIR_WO_941303_TV15204_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0103
Downstream MH
15 0102
Dir. of Survey
Downstream
Length Surveyed
293.6 ft.
Total Length
293.6 ft.
Structural Index
3
Structural Quick
413E
Structural Rating
102
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
106
Pipe schematic from manhole 15 0103 to 15 0102
MH: 15 0103MH: 15 0102downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 01030 ft. MWL - Water Level, 10 %of cross sectional area4.2 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES16.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"19.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"52.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"53.7 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES57 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"57.2 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start61.1 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Finish63.6 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES112.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"116.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"138 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES144.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start157.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"169.3 ft. RBL - Roots Ball Lateral, at 02 o'clock, 55 %169.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"188.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"208.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"210.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"265.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"269.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"291.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish293.6 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK293.6 ft. AMH - Downstream Manhole, Survey Ends - 15 0102

Observation photos (6)

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    4.2 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    53.7 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start

    57.2 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    63.6 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    138 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    144.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (27)

DistanceCodeObservation
57TF
291.4CM
0MWM
57.2FL
293.6MGOCONNECTION AT THE MH 9 OC'LOCK
144.1CM
16.9TF
53.7FL
157.3TF
265.4TFC
293.6AMH15 0102
269.2TF
4.2CL
52.3TFC
63.6FM
210.9TF
188.1TFC
116.5TF
112.4TF
61.1FL
19.3TF
208.2TF
169.3RBL
169.3TF
0AMH15 0103
138CM
0MWL

Properties (7)

additional_info
630074032122201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-03-21T23:21:19-07:00
documentation
PROPIPE
is_lateral_inspection
false