Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 18, 2022, 08:07 AM
  • C 0560_C 0559_03182022_011756.mp4

Date
03/18/2022
W/O
941898
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00362
PipeID
P04744
Time
1:07 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9925
Sewer Name
C JOINT OUTFALL C - UNIT 4D
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
12
Purpose
Routine Assessment
Project
WO_941898_TV03080_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
15 in.
Upstream MH
C 0560
Downstream MH
C 0559
Dir. of Survey
Downstream
Length Surveyed
402.2 ft.
Total Length
402.2 ft.
Structural Index
2
Structural Quick
2600
Structural Rating
12
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
12
Pipe schematic from manhole C 0560 to C 0559
MH: C 0560MH: C 0559downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK CAPPED0 ft. AMH - Upstream Manhole, Survey Begins - C 05600 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area7.1 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES201.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES345.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start365.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish402.2 ft. AMH - Downstream Manhole, Survey Ends - C 0559

Observation photos (3)

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    7.1 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    201.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    345.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
201.2CL
0MGOCONNECTION AT THE MH 9 OC'LOCK CAPPED
345.9CL
0AMHC 0560
402.2AMHC 0559
0MWL
7.1CL
0MWM
365.4CL

Properties (7)

additional_info
630074031722202
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-03-18T01:07:36-07:00
documentation
PROPIPE
is_lateral_inspection
false