Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 23, 2022, 10:40 AM
  • B 0346_B 0331_03232022_034309.mp4

Date
03/23/2022
W/O
941327
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00090
PipeID
P08858
Time
3:40 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9935
Sewer Name
B JOINT OUTFALL B - UNIT 4B
City
TEMPLE CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
15
Purpose
Routine Assessment
Project
WO_941327_TV15045_MAR2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
21 in.
Width
90 in.
Upstream MH
B 0346
Downstream MH
B 0331
Dir. of Survey
Downstream
Length Surveyed
31.9 ft.
Total Length
31.9 ft.
Structural Index
3
Structural Quick
3500
Structural Rating
15
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
15
Pipe schematic from manhole B 0346 to B 0331
MH: B 0346MH: B 0331downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 03463.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start30.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish31.9 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK CAPPED31.9 ft. AMH - Downstream Manhole, Survey Ends - B 0331

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
3.3SAV
31.9MGOCONNECTION AT THE MH 9 OC'LOCK CAPPED
30.4SAV
0MGOCONNECTION AT THE MH 3 OC'LOCK
31.9AMHB 0331
0MWL
0MWM
0AMHB 0346

Properties (7)

additional_info
630074032222202
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-03-23T03:40:11-07:00
documentation
PROPIPE
is_lateral_inspection
false