Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 9, 2022, 09:32 AM
  • 18 0183_18 0182_03092022_024311.mp4

Date
03/09/2022
W/O
941308
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00695
PipeID
P14008
Time
1:32 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9916
Sewer Name
18 ORR AND DAY ROAD TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
19
Purpose
Routine Assessment
Project
WO_941308_TV18043_MAR2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
18 0183
Downstream MH
18 0182
Dir. of Survey
Downstream
Length Surveyed
290.7 ft.
Total Length
290.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 18 0183 to 18 0182
MH: 18 0183MH: 18 0182downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 01830 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK2.2 ft. MGO - General Observation - MAG COAT127.1 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"182.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"189.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"227 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"290.7 ft. AMH - Downstream Manhole, Survey Ends - 18 0182

Observations (11)

DistanceCodeObservation
0MWL
227TF
127.1TF
290.7AMH18 0182
189.6TF
2.2MGOMAG COAT
182.2TF
0MGOCONNECTION AT THE MH 9 OC'LOCK
0MWM
0AMH18 0183
0MGOCONNECTION AT THE MH 3 OC'LOCK

Properties (7)

additional_info
630074030822201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2022-03-09T01:32:58-08:00
documentation
PROPIPE
is_lateral_inspection
false