Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 9, 2022, 10:27 AM
  • 18 0179_18 0178_03092022_034126.mp4

Date
03/09/2022
W/O
941308
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00695
PipeID
P14004
Time
2:27 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9916
Sewer Name
18 ORR AND DAY ROAD TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
19
Purpose
Routine Assessment
Project
WO_941308_TV18043_MAR2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
18 0179
Downstream MH
18 0178
Dir. of Survey
Downstream
Length Surveyed
381 ft.
Total Length
381 ft.
Structural Index
3
Structural Quick
5232
Structural Rating
20
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
20
Pipe schematic from manhole 18 0179 to 18 0178
MH: 18 0179MH: 18 0178downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 01792.2 ft. MGO - General Observation - MAG COAT203.5 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO340.8 ft. SRV - Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: NO368.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start368.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start378.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish378.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish381 ft. AMH - Downstream Manhole, Survey Ends - 18 0178

Observation photos (4)

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

    203.5 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: NO

    340.8 ft. - Surface Reinforcement Visible, at 02 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    368.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    368.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0MWM
368.1SAV
0MGOCONNECTION AT THE MH 3 OC'LOCK
0MWL
2.2MGOMAG COAT
378.4SAV
0AMH18 0179
203.5SRV
368.1SSS
378.4SSS
340.8SRV
381AMH18 0178

Properties (7)

additional_info
630074030822201
custom_field_three
REINFORCEMENT VISIBLE/AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-03-09T02:27:37-08:00
documentation
PROPIPE
is_lateral_inspection
false