Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 9, 2022, 11:48 AM
  • 18 0174_18 0426_03092022_045057.mp4

Date
03/09/2022
W/O
941308
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00695
PipeID
P13999
Time
3:48 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9916
Sewer Name
18 ORR AND DAY ROAD TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
19
Purpose
Routine Assessment
Project
WO_941308_TV18043_MAR2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
18 0174
Downstream MH
18 0426
Dir. of Survey
Downstream
Length Surveyed
11.1 ft.
Total Length
11.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 18 0174 to 18 0426
MH: 18 0174MH: 18 0426downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK CAPPED0 ft. AMH - Upstream Manhole, Survey Begins - 18 01740 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED0 ft. MWL - Water Level, 15 %of cross sectional area2.2 ft. MGO - General Observation - MAG COAT11.1 ft. AMH - Downstream Manhole, Survey Ends - 18 042611.1 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK

Observations (8)

DistanceCodeObservation
0MWM
0MGOCONNECTION AT THE MH 9 OC'LOCK CAPPED
0AMH18 0174
0MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
11.1AMH18 0426
0MWL
2.2MGOMAG COAT
11.1MGOCONNECTION AT THE MH 9 OC'LOCK

Properties (7)

additional_info
630074030822201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2022-03-09T03:48:32-08:00
documentation
PROPIPE
is_lateral_inspection
false