Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 7, 2022, 12:15 PM
  • 18 0204_18 0203_03072022_053312.mp4

Date
03/07/2022
W/O
941308
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00695
PipeID
P14029
Time
4:15 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9914
Sewer Name
18 ORR AND DAY ROAD TRUNK
City
SANTA FE SPRINGS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
13
Purpose
Routine Assessment
Project
WO_941308_TV18043_MAR2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
18 0204
Downstream MH
18 0203
Dir. of Survey
Downstream
Length Surveyed
301.1 ft.
Total Length
301.1 ft.
Structural Index
3
Structural Quick
543K
Structural Rating
315
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
315
Pipe schematic from manhole 18 0204 to 18 0203
MH: 18 0204MH: 18 0203downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 02040 ft. MGO - General Observation - HEAVY STEAM2.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start223.9 ft. SRV - Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: NO, Start229.5 ft. SRV - Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: NO, Finish283.7 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO, Start298.7 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish298.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish298.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish301.1 ft. AMH - Downstream Manhole, Survey Ends - 18 0203301.1 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK301.1 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: NO, Start

    223.9 ft. - Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: NO, Start

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO, Start

    283.7 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO, Start

Observations (15)

DistanceCodeObservation
0MWL
298.7SRV
0MWM
223.9SRV
298.7SSS
301.1AMH18 0203
0AMH18 0204
2.5SAV
229.5SRV
301.1MGOCONNECTION AT THE MH 9 OC'LOCK
2.5SSS
301.1MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
0MGOHEAVY STEAM
298.7SAV
283.7SRV

Properties (7)

additional_info
630074030722003
custom_field_three
REINFORCEMENT VISIBLE/AGGREGATE VISIBLE
custom_field_two
2
customer
1
datetime
2022-03-07T04:15:00-08:00
documentation
PROPIPE
is_lateral_inspection
false