Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 14, 2022, 07:54 AM
  • 18 0159_18 0158_03142022_010103.mp4

Date
03/14/2022
W/O
941308
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00695
PipeID
P13982
Time
12:54 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9919
Sewer Name
18 ORR AND DAY ROAD TRUNK
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
24
Purpose
Routine Assessment
Project
WO_941308_TV18043_MAR2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
18 0159
Downstream MH
18 0158
Dir. of Survey
Downstream
Length Surveyed
221.9 ft.
Total Length
221.9 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
129
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
129
Pipe schematic from manhole 18 0159 to 18 0158
MH: 18 0159MH: 18 0158downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 01590 ft. MWL - Water Level, 20 %of cross sectional area0.1 ft. MWM - Water Mark, 35 %of cross sectional area2.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.5 ft. MGO - General Observation - MAG COAT219.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish221.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0158221.9 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
221.9AMH18 0158
221.9MGOCONNECTION AT THE MH 3 OC'LOCK
0AMH18 0159
2.5SAV
2.5MGOMAG COAT
0MWL
0.1MWM
219.3SAV

Properties (7)

additional_info
630074031422061
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2022-03-14T00:54:45-07:00
documentation
PROPIPE
is_lateral_inspection
false