Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 8, 2022, 07:19 AM
  • 18 0198_18 0197_03082022_004432.mp4

Date
03/07/2022
W/O
941308
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00695
PipeID
P14023
Time
11:19 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9915
Sewer Name
18 ORR AND DAY ROAD TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
13
Purpose
Routine Assessment
Project
WO_941308_TV18043_MAR2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
18 0198
Downstream MH
18 0197
Dir. of Survey
Downstream
Length Surveyed
403.7 ft.
Total Length
403.7 ft.
Structural Index
3
Structural Quick
5C3O
Structural Rating
490
O&M Index
2
O&M Quick
2I00
O&M Rating
102
Overall Index
3
Overall Quick
Overall Rating
592
Pipe schematic from manhole 18 0198 to 18 0197
MH: 18 0198MH: 18 0197downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 01980 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area2.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start10.6 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start96.5 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish135.3 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES146.9 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start399.8 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish399.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish399.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish403.7 ft. AMH - Downstream Manhole, Survey Ends - 18 0197

Observation photos (5)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    10.6 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES

    135.3 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES

  • Deposits Settled Other,  10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    146.9 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
2.1SSS
403.7AMH18 0197
0AMH18 0198
0MWM
146.9DSZ
10.6SRV
399.8DSZ
399.8SSS
96.5SRV
2.1SAV
399.8SAV
0MWL
135.3SRV

Properties (7)

additional_info
630074030722201
custom_field_three
REINFORCEMENT VISIBLE/SPALLING/AGGREGATE VISIBLE
custom_field_two
2
customer
1
datetime
2022-03-07T23:19:08-08:00
documentation
PROPIPE
is_lateral_inspection
false