Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 15, 2022, 08:02 AM
  • C 0384_C 0383_03152022_011937.mp4

Date
03/15/2022
W/O
941947
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00142
PipeID
P09848
Time
1:02 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9961
Sewer Name
C JOINT OUTFALL C - UNIT 8D
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_941947_TV19067_MAR2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
18 in.
Upstream MH
C 0383
Downstream MH
C 0384
Dir. of Survey
Upstream
Length Surveyed
275.9 ft.
Total Length
275.9 ft.
Structural Index
3
Structural Quick
5J3J
Structural Rating
540
O&M Index
3
O&M Quick
5132
O&M Rating
14
Overall Index
3
Overall Quick
Overall Rating
554
Pipe schematic from manhole C 0383 to C 0384
MH: C 0383MH: C 0384upstream0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - C 038410.6 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES10.6 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish10.6 ft. IS - Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES49.9 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES91.8 ft. IG - Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES154.6 ft. IS - Infiltration Stain, from 02 to 04 o'clock, within 8 inches of joint: YES245.9 ft. LR - Alignment Right, 10 %262 ft. IS - Infiltration Stain, from 12 to 04 o'clock, within 8 inches of joint: YES267.9 ft. LL - Alignment Left, 15 %273.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start273.9 ft. MGO - General Observation - MAG COATING273.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start273.9 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start275.9 ft. MWM - Water Mark, 25 %of cross sectional area275.9 ft. AMH - Downstream Manhole, Survey Begins - C 0383275.9 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (12)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COATING

    2 ft. - General Observation - MAG COATING

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Alignment Left, 15 %

    8 ft. - Alignment Left, 15 %

  • Infiltration Stain, from 12 to 04 o'clock, within 8 inches of joint: YES

    13.9 ft. - Infiltration Stain, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Alignment Right, 10 %

    30 ft. - Alignment Right, 10 %

  • Infiltration Stain, from 02 to 04 o'clock, within 8 inches of joint: YES

    121.3 ft. - Infiltration Stain, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES

    184.1 ft. - Infiltration Gusher, at 04 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    226 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    265.3 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES

    265.3 ft. - Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
0MWM
275.9SAP
0AMHC 0383
2SSS
8LL
275.9SSS
2MGOMAG COATING
2SAP
30LR
13.9IS
275.9AMHC 0384
2SRV
184.1IG
121.3IS
265.3ID
0MWL
226ID
265.3SRV
265.3IS

Properties (8)

additional_info
630098031422201
custom_field_three
INFILTRATION, REINFORCEMENT VISIBLE
custom_field_two
1
customer
1
datetime
2022-03-15T01:02:14-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
26643